1 closing contact not isolated 10 A/250 V/AC, incandescent bulbs up to 2000 W, ESL and LED-lamps up to 200W, switch-off pre-warning and scanner light can be attached. By-Verlust of only 0.7 W. With ESL-optimization. For mounting. 45 mm long, 55 mm wide,...
No coil-power loss and heat generation in a switched state through the use of a bi-stable relay. The contact switching takes place to protect the contacts and devices in the zero crossing. A switch-off warning and a continuous button-light can be switched...
1-10V control dimming switch 1-10V for electronic ballast. 1 NO non-potential free 600VA and 1-10V control output 40mA. Stand-by loss only 1 watt. Adjustable dimming speed. With children's room and snooze switch. With button or switch control. For panel...
With control inputs for light sensor and light switches For protection of lamps, the switching is done in zero point with soft on and soft off. In addition to the minimum brightness, even dimming can be adjusted, whereby at the same time, the duration...
Universal dimming switch. Power MOSFET up to 400W. Automatic lamp detection. Stand-by loss only 0.1 watt. Minimum brightness or dimming speed can be set. With children's room and snooze switch. For panel mounting. 45mm long, 45mm wide, 18mm deep. Universal...
Without N-connection, Power MOSFET up to 200W. Standby loss of only 0.5 watts. With control inputs for light sensor and light switches Minimum brightness, operating mode and dimming speed can be set. For panel mounting. 45mm long, 45mm wide, 18mm deep....
LED DIMMING SWITCH 12-36V DC. Power MOSFET for LED lamps 12-36V DC to 4A, pulse width modulation PWM. Stand-by loss only 0.1 watt. Minimum brightness and dimming speed can be set. With children's room and snooze switch. For panel mounting. 45mm long,...
Only calibrated meters are approved for electricity accounting according to §25 of the German calibration law. Non-compliance is an administrative offense according to §19. RS485-Bus radio three-phase meter. Maximum current 3x80A, standby loss only...
Only calibrated meters are permitted for electricity billing in accordance with paragraph 25 of the German Calibration Act. Non-compliance is an irregularity in accordance with paragraph 19. RS485-bus two-way three-phase meter. Maximum current 3x80A,...
Only calibrated meters are approved for electricity accounting according to §25 of the German calibration law. Non-compliance is an administrative offense according to §19. Maximum current 3x80A, standby loss of only 0.5 watts per path. Series installation...
Maximum current 3x80A, standby loss of only 0.5 watts per path. Series installation device for mounting on DIN-EN 60715 TH35 mounting rail. 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. The direct measuring three-phase...
Only calibrated meters are approved for electricity accounting according to §25 of the German calibration law. Non-compliance is an administrative offense according to §19. M-Bus three-phase meter. Maximum current 3x80A, standby loss of only 0.5 watts...
Maximum current 3x80A, standby loss only 0.5 watts per path. DIN-EN 60715 TH35 DIN rail mounting device. 4 divisions = 70mm wide, 58mm deep. Accuracy class B (1%). With S0 interface. The directly measuring three-phase meter measures the active energy...
Only calibrated meters are approved for electricity accounting according to §25 of the German calibration law. Non-compliance is an administrative offense according to §19. Converter three-phase meter with adjustable converter ratio and MID. Maximum...
Only calibrated meters are approved for electricity accounting according to §25 of the German calibration law. Non-compliance is an administrative offense according to §19. M-Bus converter three-phase meter with adjustable converter ratio and MID. Maximum...